FEI-Zyfer, Inc. Frequency Electronics, Inc. FEI-Zyfer, Inc.
GPS Time and Frequency Systems
 
 

prev 1 2 3 4 next

 

System Control I/O Modules

System Control I/O modules are used in modular systems like the CommSync II, CommSync II-D, GSync and GSync II to provide remote control and monitoring.  In addition, they accept external synchronization input for DTF (Distribution Time and Frequency) systems. Communication with the System Control modules is via an RS-232 or Ethernet interface. Ethernet versions also provide control and monitoring via the Zyfer Monitor GUI as well additional functionality such as NTP, SNTP and PTPv2.

Dual Port Ethernet I/O

 
IEEE 1588-2008 Precision Time Protocol (PTP v2)
  
 
 

Description Part No.  
 



Dual Port Ethernet I/O Module - IEEE 1588-2008 Precision Time Protocol (PTP v2) - Provides two independent 10/100 Base-Tx TCP/IP Ethernet ports for remote configuration, control and monitoring of the system via Telnet, Simple Network Management Protocol (SNMP versions 1, 2c, and 3), or Secure Shell (SSH).  In addition, the 385-4097-01 provides PTP GrandMaster or Slave capability.  PTP is available on port '0' only. Dual independent Ethernet ports allow the 385-4097 to be connected to separate networks and to perform separate functions simultaneously. The module supports IPv4 and IPv6 addressing, and also provides Network Time Services (NTS) with Network Time Protocol (NTP versions 1, 2 & 3) and Simple NTP (SNTP), enabling the system to perform as an network time server on the most advanced networks. Two RJ-45 connectors, one DE-9 (RS-232) and four status LED's. 385-4097-01  
         
 



Dual Port Ethernet I/O Module with 1 PPS & 1, 5 & 10MHz BNC External Inputs - IEEE 1588-2008 Precision Time Protocol (PTP v2) - Provides two independent 10/100 Base-Tx TCP/IP Ethernet ports for remote configuration, control and monitoring of the system via Telnet, Simple Network Management Protocol (SNMP versions 1, 2c, and 3), or Secure Shell (SSH). In addition, the 385-4097-02 provides PTP GrandMaster or Slave capability.  PTP is available on port '0' only. Dual independent Ethernet ports allow the 385-4097 to be connected to separate networks and to perform separate functions simultaneously. The module supports IPv4 and IPv6 addressing, and also provides Network Time Services (NTS) with Network Time Protocol (NTP versions 1, 2 & 3) and Simple NTP (SNTP), enabling the system to perform as an network time server on the most advanced networks. Two RJ-45 connectors, two BNC (F) connectors for External Reference 1 PPS Sync Inputs or External 1, 5 or 10 MHz Frequency Inputs and four status LED's. 385-4097-02  
         
 



Dual Port Ethernet I/O Module with 1, 5 & 10MHz Fiber Optic External Inputs - IEEE 1588-2008 Precision Time Protocol (PTP v2) - Provides two independent 10/100 Base-Tx TCP/IP Ethernet ports for remote configuration, control and monitoring of the system via Telnet, Simple Network Management Protocol (SNMP versions 1, 2c, and 3), or Secure Shell (SSH).  In addition, the 385-4097-03 provides PTP GrandMaster or Slave capability.  PTP is available on port '0' only. Dual independent Ethernet ports allow the 385-4097 to be connected to separate networks and to perform separate functions simultaneously. The module supports IPv4 and IPv6 addressing, and also provides Network Time Services (NTS) with Network Time Protocol (NTP versions 1, 2 & 3) and Simple NTP (SNTP), enabling the system to perform as an network time server on the most advanced networks. Two RJ-45 connectors, two ST Fiber Optic Connectors for External Reference 1, 5 or 10 MHz Frequency Inputs and four status LED's. 385-4097-03  
         
 



Dual Port Ethernet I/O Module with 10 VDC 1 PPS BNC External Inputs -
IEEE 1588-2008 Precision Time Protocol (PTP v2)
- Provides two independent 10/100 Base-Tx TCP/IP Ethernet ports for remote configuration, control and monitoring of the system via Telnet, Simple Network Management Protocol (SNMP versions 1, 2c, and 3), or Secure Shell (SSH).  In addition, the 385-4097-04 provides PTP GrandMaster or Slave capability.  PTP is available on port '0' only. Dual independent Ethernet ports allow the 385-4097 to be connected to separate networks and to perform separate functions simultaneously. The module supports IPv4 and IPv6 addressing, and also provides Network Time Services (NTS) with Network Time Protocol (NTP versions 1, 2 & 3) and Simple NTP (SNTP), enabling the system to perform as an network time server on the most advanced networks. Two RJ-45 connectors, two BNC (F) connectors for External Reference 10 VDC 1 PPS Sync Inputs and four status LED's.
385-4097-04  
 
 
   
         
   
 

prev 1 2 3 4 next

 
   